ShanBo
Location:Home>News Center

-News Center-

Which Capability to Upgrade for Deep Water Supply Projects

Date:2026-11-15 10:01:26Views:17

In the equipment discussion stage of deep water supply projects, the most common phrase is to state the target well depth and then ask "which machine can drill that deep." However, what really determines whether to upgrade the equipment tier is often not just the drilling depth number, but the completion diameter and well casing/pump type, the handling volume of drill string and casing, whether a down-the-hole hammer is used in hard rock sections, and whether the entire rig can access the site smoothly. Drilling depth is merely the first item mentioned among these conditions.

Below, following the approach of "requirement decomposition," we break down the operational goals of deep water supply into verifiable condition items, and then compare them with the specifications of the 1200 m class truck-mounted straight mast water well rig to explain which features correspond to which requirements and which values cannot be casually taken as conclusions.

First, clarify what kind of well is to be completed

The goal of a water supply well is not to drill a hole, but to complete a well that can install casing, run a pump, and produce water stably. Therefore, before selecting equipment, at least the following items should be clearly defined:

  • Target hole depth and the depth interval of the expected main aquifer;
  • Completion diameter and planned well casing, screen specifications, and submersible pump outer diameter;
  • Approximate thickness of upper loose layers, middle weathered/fractured zones, and deep hard rock;
  • Whether DTH hammer drilling is used, and if so, whether air supply conditions can be secured;
  • Number and distribution of well sites, determining whether mobilization is by truck road travel or point-to-point transport.

Among these, diameter and casing often push the equipment up earlier than drilling depth. The deeper the hole and the larger the diameter, the drill pipe weight, casing weight, cuttings removal demand, and air supply load all increase simultaneously. Conversely, if the final hole diameter is not large and casing specifications are limited, upgrading the equipment tier based solely on drilling depth may raise mobilization and relocation costs.

Drilling depth as capability reserve does not mean every well is drilled to the limit

The maximum drilling depth of this equipment is 1200 m. This figure should be understood as the equipment capability upper limit, not the actual completion depth under any formation conditions. The actual achievable depth is also constrained by final hole diameter, drill string assembly, formation stability, and cuttings removal effectiveness.

Which Capability to Upgrade for Deep Water Supply Projects

For deep water supply projects, the significance of this depth reserve is: when shallow aquifers have insufficient water and deeper intervals need to be verified, the equipment does not need to be replaced midway due to insufficient depth. However, it does not constitute a judgment that "this depth will definitely complete a well"; aquifer location and water quality still need to be determined by hydrogeological work.

Diameter range should be considered together with casing and pump type

The drilling diameter range of this equipment is 105–900 mm. This range covers possibilities from conventional deep water wells to larger diameter groundwater wells, but the upper limit should not be directly adopted in design.

Larger hole diameters facilitate larger casing and submersible pumps, at the cost of increased drill string load, casing weight, cuttings removal air volume, and air compressor load. Therefore, in the planning stage, the reasonable sequence is to first determine the water yield target and pump type, then determine the casing, and finally derive the required completion diameter, rather than arranging procedures based on the equipment's maximum diameter first.

What is really tight in deep hole sections is drill string and casing handling

As hole depth increases, the frequency of tripping, single-run drill string weight, and hole wall friction all change. The specifications give this equipment a lifting force of 61 T, axial pressure of 13 T, recommended drill pipe diameter of 127 mm, and drill pipe length options of 3 m or 6 m. These data correspond precisely to the drill string and casing handling stage in deep hole sections.

Lifting force is one of the upper limits of handling capacity. When abnormal tripping resistance is encountered on site, the correct sequence is still to first clean the hole and assess hole wall and sediment conditions, rather than pulling with maximum lifting force. This is especially important in deep holes, because the cost of dealing with drill string or hole wall problems caused by one forced pull is significantly higher than in shallow holes.

Which Capability to Upgrade for Deep Water Supply Projects

The choice of drill pipe length is related to process organization: 6 m drill pipes reduce the number of connections, while 3 m drill pipes are more flexible in transport and restricted sites. Both lengths are supported, meaning that during configuration, trade-offs can be made according to site conditions rather than being locked into a single specification.

Whether to use DTH hammer in hard rock sections depends on whether air supply can be simultaneously satisfied

The specifications state that this equipment can be configured with medium and high pressure DTH hammers for DTH drilling in relatively intact hard rock, with recommended working air pressure of 1.65–8 MPa and air consumption of 16–120 m³/min.

Special attention is needed here: the pressure range and air consumption range are supporting conditions, not self-contained capabilities of the equipment. Deep holes and large diameters in hard rock impose high pressure and displacement requirements on the air compressor. Meeting pressure alone while displacement is insufficient can still result in insufficient impact, difficult cuttings removal, and bottom-hole sediment accumulation. Therefore, the air supply plan must be secured in advance as an independent condition, and cannot be temporarily matched after the equipment arrives on site.

Upper formations and strong aquifers determine the process, not the depth

The specifications provide segmented treatment directions for formations: soil, clay, sand, and gravel layers can use mud rotary, casing, or other hole stabilization methods; weathered rock and fractured zones require controlled advancement, enhanced hole cleaning, and if necessary, casing or foam assistance; after entering the main aquifer, water inflow will change cuttings removal and downhole pressure conditions, requiring recording of the water-producing zone depth and adjustment of air supply, hole cleaning, and casing plans.

These contents indicate that the difficulties of deep water supply wells are often concentrated in the upper hole sections and aquifer interfaces, rather than the final hole depth. Early hole collapse, diameter reduction, or casing problems will be amplified in subsequent deep construction. Equipment selection must therefore be determined together with the drilling process, and cannot rely solely on comparing machine parameters.

Which Capability to Upgrade for Deep Water Supply Projects

Mobilization method and site access conditions should be checked simultaneously

This equipment has a truck-mounted straight mast structure, with a total weight of approximately 32 T and transport dimensions of approximately 11.5 × 2.25 × 3.2 m. The significance of truck mounting is to reduce repeated loading and unloading between projects, suitable for deep well projects in mining areas, industrial parks, farms, and other locations requiring cross-regional mobilization.

However, the straight mast structure has a relatively fixed transport profile. Before site access, road width, bridge load capacity, turning radius, site bearing capacity, and overhead clearance need to be verified. These are items to be confirmed; the specifications themselves do not constitute a judgment on the passability of any specific road.

Arrange capability items into a checklist

Operating ConditionCorresponding Item in SpecificationsStill to be Confirmed
Target hole depthMaximum drilling depth 1200 mMain aquifer depth, final hole diameter
Completion diameter and pump typeDrilling diameter 105–900 mmWell casing, screen, submersible pump outer diameter
Drill string and casing handlingLifting force 61 T, axial pressure 13 T, 127 mm drill pipeCasing specifications and weight, tripping organization
Hard rock drillingDTH recommended air pressure 1.65–8 MPa, air consumption 16–120 m³/minWhether air compressor pressure and displacement can be simultaneously satisfied
Mobilization and site accessTruck-mounted straight mast, total weight approx. 32 TRoad height/width limits, bridge load capacity, site clearance

The use of this table is to implement row by row from left to right, rather than inferring the project from equipment parameters. If any row lacks information, conditions should be supplemented first before discussing whether the equipment tier is appropriate.

Information to provide before inquiry

If the deep water supply project is to be advanced to the equipment inquiry stage, it is recommended to prepare the following information: drilling purpose and water supply scale; estimated formation column description and main aquifer depth; target hole depth and completion diameter; planned well casing and pump type; whether DTH hammer is used and air supply conditions; number and distribution of well sites; access road and site conditions; on-site power supply or diesel power arrangements. The more complete the information, the better the judgment can be made as to whether this 1200 m class truck-mounted straight mast equipment just covers the capability or whether some condition requires additional supporting equipment.